top of page
waterfall diagram for CSL test

ASTM D5882-16 

Compliance Statement

ASTM D5882-16: Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations

[Link to the ASTM standard] [Compliance certificate (PDF, 194Kb)]

Piletest.com confirms that our PET system, running PET Version 3.00 (or higher) meet, or exceed, the requirements of ASTM Standard D5882-07 (2013).

Specific itemized compliance break-down list:

Item
Description
Requirements
Compliance
5.1.1
Impact force application
Hammer with hard plastic tip
Provided
5.2.1
Calibration accuracy
5%  
Exceeds (1% accuracy)
5.2.1.
Resonant frequency
≥ 30 kHz
Meets  
5.2.1.
Accelerometer time constant
≥0.5 sec
Meets
5.2.1.
Accelerometer linearity
Up to 50 g
Meets
5.3.
Signal transmission
Low-noise shielded cable
Exceeds (Digital transmission + error correction)
5.4.1.
Apparatus
Permanent data storage capability
Provided (computer hard disk)
5.4.1.
Apparatus
Permanent graphic display
Provided (computer screen)
5.4.1.
Apparatus
Variable amplification
Provided by software
5.4.1.
Apparatus
Filtering capability
Provided by software
5.4.1.
Apparatus
Blow averaging capability
Provided by software
5.4.2.
Clock jitter
≤0.01%
Exceeds
5.4.2.
Recording apparatus
12 bit A/D resolution
Exceeds: 24 bits PET Pro USB model 16 bit PET Bluetooth Model
5.4.2.
Sample frequency
25 kHz
Exceeds (50 kHz)
5.4.4.
Signal duration scale
2 L/c plus 5 msec
Exceeds
bottom of page