PET
Pile Echo Tester
PET is used to test the integrity of deep pile foundations. PET Uses the pulse-echo method (PEM) for pile integrity testing (PIT). A pile test starts when the pile top is struck with a hammer, and the PET accelerometer records the reflected waves, which are displayed as a reflectogram.
-
Smart Trigger for ease of use
-
Automatic Impulse sorting
-
ASTM D5882-16, AFNOR P160-2,4
-
Rugged and IP68 waterproof
Applications
This is the primary method used in the industry for a quick pile integrity test to control the quality of piles on a site. This simple and fast test method makes it practical to test 100% of the piles, even on sites with many piles.
Rugged and Easy to Use Pile Integrity Test Equipment
Reliable
-
Specially designed and tested for a hostile construction environment.
-
IP68 (Protection against complete, continuous submersion in water).
-
3 years warranty!
-
10 years of free software
Easy to Use
-
Usually, no training is needed, and the system can be self-taught in a few hours. (No expensive training days)
-
Unique Smart Trigger for fast & easy quality results.
Top Performance
-
Up to 100 piles/hour can be tested.
-
Very low noise level extends the usual limits of the pile integrity test method to longer piles.
-
Automatic Impulse sorting
Pile integrity test team on site using PET in Pakistan
Pile integrity test team on site using PET in Africa
Pile integrity test team on site using PET in Greece
Pile integrity test team on site using PET in Pakistan
PET USB - Technical Specifications
Physical
Housing
Dimentions
Weight
Temprture range
Waterproofing
Industrial grade transducer enclosed in a durable stainless steel and aluminum housing
30 mm (diameter) x 90 mm (Length)
120gr (Transducer)
2.3kg (Shipping)
-20°C to +55°C (Operating)
-40°C to +80°C (Storage)
IP67 (Protection against submersion in water)
Transducer
Sensitivity
Linearity
Resonance frequency
Sampling frequency
Sampling resolution
100mV/g
Within 1%, 0 to 50g
30kHz
50kHz
24bit
Standards
ASTM D5882-16
AFNOR P160-2,4
CE
Meets or exceeds
In conformity to all the essential requirements of CE EMC & Safety requirements Directive 2014/30/EU and Low Voltage Directive LVD 2014/35/EU
Technical Features
Trigger
Smart Trigger
Auto sort
Pile Averaging
Site Averaging
Variable trigger level
Trigger by impulse shape
Automatic sorting of best impacts
Averaging all good impacts -
Clears the noise from the reflectogram
Average between several piles reflecting site conditions
Performance
Pile lengths
Productivity
Max cable length
Max record impulse
Resolution
Storage
2m to 80m
(depending on diameter and soil profile. )
Up to 100 piles/hour by a single operator
under favorable conditions
Up to 4m with cable extension (2m extension included)
100ms
16bit
Upto 1Tera byte
Requirements
Computer
(Not included )
Windows Win7/Win10/Win11.
800x600 resolution or better
USB port
Recommended: Tablet PC (outdoor display)
Output
Reporting
Language
Time/Distance Reflectogram
FFT analysis - Standard
Multi-lingual user interface and reporting
Power
USB cable
Powered by the attached Computer/Tablet
No power limits when used with a replaceable battery computer, or backup computer/tablet.
PET Bluetooth (wireless) - Technical Specifications
Physical
Housing
Dimentions
Weight
Temprture range
Waterproofing
Industrial grade transducer enclosed in a durable stainless steel and aluminum housing
34 mm (diameter) x 120 mm (Length)
155gr (Transducer)
3kg (Shipping)
-20°C to +55°C (Operating)
-40°C to +80°C (Storage)
IP67 (Protection against submersion in water)
Transducer
Sensitivity
Linearity
Resonance frequency
Sampling frequency
Sampling resolution
100mV/g
Within 1%, 0 to 50g
30kHz
50kHz
16bit
Standards
ASTM D5882-16
AFNOR P160-2,4
CE
Meets or exceeds
In conformity to all the essential requirements of RED 2014/53/EU
Technical Features
Triger
Smart Trigger
Auto sort
Pile Averaging
Site Averaging
Variable trigger level
Trigger by impulse shape
Automatic sorting of best impacts
Averaging all good impacts -
Clears the noise from the reflectogram
Average between several piles reflecting site conditions
Performance
Pile lengths
Productivity
Wireless range
Max record impulse
Resolution
Storage
2m to 80m
(depending on diameter and soil profile. )
Up to 100 piles/hour by a single operator
under favorable conditions
Up to 10m between the transducer and the Android device
100ms
24bit
Upto 1Tera byte
Requirements
Computer
(Not included )
Windows Win7/Win10/Win11.
800x600 resolution or better
Bluetooth suport
Recommended: Android Smartphone or Tablet (outdoor display)
Output
Reporting
Language
Time/Distance Reflectogram
FFT analysis - Standrad
Multi-lingual user-interface and reporting
AAA Battaries
2 X AAA Alkaline batteries, 3V total. Sufficient for testing approximately 300 piles. Easily replaceable in the field.
Power
Other Customers Also Purchased
GPC
GPC the PDA system from Piletest
It is the next generation of dynamic pile testing systems, designed with simplified software and higher ease of use than incumbent systems. Professor George G. Goble, the pioneer of dynamic pile analyzers, designed the GPC system. It comes with a unique Combiducer and 100% lossless wireless data transmission,
3DT
3 Dimensional Tomography
While normal (1D) CSL can only show the depth of an anomaly, tomography can help in the visualization of the shape, size, and location of anomalies. It is an analysis and presentation method of captured CSL data, that projects the logged results into two dimensional (2D) plane or three dimensional (3D) body.
CHUM
Cross Hole Ultrasonic Monitor
CHUM supports Cross-hole Sonic Logging (CSL) for testing the integrity of deep pile foundations. It also supports on-site tomography measurements for real-time two-dimensional Tomography (2DT) presentation. Based on that tomography data, true 3D Tomography analysis can be presented.
-
12345678 Example Accessory #4This is example accessory #4 description.
-
12345678 Example Accessory #2This is example accessory #2 description.
Downloads
Documents
Software